In air is the only band this part is written for: a moulded PVC shell pushed on by hand over a cut end that will never be splashed, buried or immersed.

In air, and no further

Place the end before you place an order. If it spends its life indoors, inside a panel, in a covered bay or on a drum kept under a roof, a push-on PVC cap is enough. If it will be wetted and dried in cycles, dropped into a trench, or left in a duct that takes water, it is the wrong part, and extra wall thickness does not make it the right one.

The manufacturer's claim for this cap is protection against weathering, moisture and contamination. That is a cover over the end, not a seal into it. There is no adhesive, no mastic and no published ingress rating anywhere on its datasheet, so a fitted PVC cap resists nothing that behaves like a standing head of water. The lined caps sit beside this one in the same catalogue and get ordered by the same engineer on the same afternoon, which is how the wrong one travels to site.

What it is genuinely good at is the half of the job that has nothing to do with water: keeping swarf, dust and paint overspray out of a bore, taking the sharpness off a freshly cut end during handling, and colour-coding a bundle of ends that otherwise look alike. It comes off and goes back on, which is a property rather than a defect — a cap that has to be cut away is a poor choice for an end you intend to open next week.

PVC push-on end cap

PVC push-on end cap

A moulded polyvinyl chloride shell pushed by hand over a cut cable, rod or stud end. No heat, no tools, no adhesive, no cure time: the fit is an interference fit on the outside diameter and nothing more.

  • Pushes on by hand, so the job needs no torch and no hot-work permit
  • Custom lengths and wall thicknesses carry no tooling charge
  • Does not crack or split the way low-density polyethylene caps do in service
  • More economical than a heat-shrink end cap covering the same diameter
  • The only part described on this site whose datasheet carries a flammability result
MaterialPolyvinyl chloride, moulded
Exposure bandIn air only
What it does at the endCovers it. No lining, no ingress rating
FittingPush-on, no tools or skill required
Dielectric strength12 kV/mm minimum
Continuous operating temperature−20 °C to 115 °C
Hardness65 ± 5 Shore A
FlammabilityPass
How it is orderedAs a diameter and a length, not from a code table
ASTM D149ASTM D638ASTM D792ASTM D2240IEC 216UL 94-V0

Recorded values from the PVC cap datasheet

Test descriptionRecorded valueTest method
Dielectric strength12 kV/mm (min.)ASTM D149
Tensile strength12 N/mm² (min.)ASTM D638
Elongation350% (min.)ASTM D638
Density1.23 g/cm³ASTM D792
Hardness65 ± 5 Shore AASTM D2240
Continuous operating−20 °C to 115 °CIEC 216
FlammabilityPassUL 94-V0

Each reference in the Test method column is explained once, on what an end-cap datasheet actually proves, and nowhere else on this site.

Push-on PVC against a lined heat-shrink cap

Both of them close a cable end. Only one of them seals it, and the band the end sits in decides which, long before the diameter does.

DecisionPVC push-on capHeat-shrink cap with a lining
Exposure band it is written forIn airIn air, splash zone, buried or submerged
What happens at the endCoveredSealed by a hot-melt adhesive lining
Published ingress ratingNoneIP68 where the lining is specified
How it goes onPushed on by handGas torch, shrink temperature 125 °C
Continuous temperature−20 °C to 115 °C−40 °C to +110 °C
Taking it off againPulls off and goes back onCut away, and a fresh cap fitted
An odd length or wall thicknessMade to order at no tooling chargeTaken from the published size range
Flammability on the datasheetPassNot published

Why PVC, and why awkward sizes end up in it

Two of the reasons this cap gets specified have nothing to do with how it performs at the end.

  • It does not crack or split the way low-density polyethylene caps do. That is the manufacturer's stated reason for the material, and the whole of it — the choice buys durability in handling, not performance at depth.
  • Custom lengths and thicknesses carry no tooling charge. That is the practical reason an awkward size ends up in PVC rather than heat-shrink: a one-off length is a moulding decision, not a hunt through a code range for the nearest thing that fits.
  • Hardness is quoted at 65 ± 5 Shore A. The heat-shrink cap is quoted at 45 ± 10 Shore D, a different scale, so the two figures will not tell you which cap is tougher.
  • No torch means no hot-work permit. Where a flame is prohibited outright that is often the entire decision, worked through on closing an end where a torch is not allowed.
  • 12 kV/mm is a property of the material, not a rating for the fitted cap. An energised end is a separate part with its own procedure, covered on the live end cap.

What this cap gets asked

Is a push-on PVC cap watertight?
No. It covers the end rather than sealing into it: no adhesive lining, and no ingress rating of any kind on the datasheet. An end bound for a duct, a trench or standing water wants the lined cap, claimed to IP68 where that lining is present — Insulcap heat-shrink cable end caps.
The cap was on and the end still got wet. What went wrong?
Almost always the band rather than the part. A cover keeps weather off a dry end and does nothing against a head of water or a duct that fills. That mismatch is one of the six cases set out on why end seals fail.
How do I give a size for one?
The outside diameter over the thing being closed, and the length you want covered. No code table is published for the push-on PVC caps as it is for the heat-shrink range, so a diameter and a length are the order rather than a part number; the codes that do exist are on the size charts. The manufacturer's own page for the ordering variants is PVC caps.
Does the same cap go on a pole crown or a dock pile top?
A PVC cap is moulded for pole and pile tops too, in five sizes across a far larger diameter band; it is specified on pole caps and deliberately not re-specified here.
Can I push one over a crimped terminal in a panel?
Same band, same idea, different geometry: a cap over a lug or a stud is sized on the barrel and the palm rather than a cable outside diameter, so it is a separate moulding — terminal insulation caps.

A diameter, a length and a band

Three lines settle it: the outside diameter over the end, how much of it you want covered, and confirmation that the end stays in air for its whole working life. If the third line is not certain, say so, and the reply will quote the lined cap instead.